DITEC GLOBE Service Manual Page 18

  • Download
  • Add to my manuals
  • Print
  • Page
    / 28
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 17
18
IP1839EN • 2012-07-31
16. COMMANDS
Command Function Description
1
5 N.O. STEP-BY-STEP With DIP1=OFF, the closing of the contact activates opening
or closing operations in the following sequence: open-stop-
close-open.
Note: if automatic closing is enabled, the stop is not permanent
but lasts for a duration set by TC.
OPENING WITH
AUTOMATIC
CLOSING
With DIP1=ON and TC<MAX, the closing of the contact acti-
vates the opening operation.
OPENING WITHOUT
AUTOMATIC
CLOSING
With DIP1=ON and TC=MAX, the closing of the contact acti-
vates the opening operation.
Note: once the automation stops, the closing of the contact
performs the opposite operation to the one performed before
stop.
1
8 N.C. REVERSE
SAFETY CONTACT
The opening of the safety contact triggers a reversal of motion
(re-opening) during closing.
1
9 N.C. STOP The opening of the safety contact stops the current operation.
PRG
N.O. TRANSMITTERS
STORAGE AND
CANCELLATION
WARNING: the BIXMR2 storage module must be inserted.
Transmitter storage:
- press the PRG key (the SIG LED comes on),
- transmit the transmitter to be stored (the SIG LED ashes),
- wait 10 s to complete storage (the SIG LED goes out).
Transmitter cancellation:
- press the PRG key for 3 sec (the SIG LED ashes),
- press the PRG key for another 3 sec (the SIG LED ashes
quickly).
WARNING: make a jumper for all the N.C. contacts if not in use. The terminals with the same number
are equal.