3. TECHNICAL DATA
GLOBE7 GLOBE10
Power supply 230 V~ / 50-60 Hz 230 V~ / 50-60 Hz
Absorption 0,7 A 1,2 A
Thrust 500 N 900 N
Opening speed 0,18 m/s
0,15 m/s [chain]
0,18 m/s [belt]
Closing speed 0,12 m/s
0,10 m/s [chain]
0,12 m/s [belt]
Maximum load 7 m
2
10 m
2
Carriage maximum stroke
2760 mm
3820 mm [GLOBELV1]
2760 mm
3820 mm [GLOBEL1-GLOBELV1]
Service class 3 - FREQUENT 3 - FREQUENT
Intermittence
S2 = 30 min
S3 = 50%
S2 = 30 min
S3 = 50%
Temperature -20° C / +55° C -20° C / +55° C
Degree of protection IP10 IP10
GLOBE7J GLOBE10J
Power supply 120 V~ / 50-60 Hz 120 V~ / 50-60 Hz
Absorption 1,4 A 2,4 A
Thrust 500 N 900 N
Opening speed 0,18 m/s
0,15 m/s [chain]
0,18 m/s [belt]
Closing speed 0,12 m/s
0,10 m/s [chain]
0,12 m/s [belt]
Maximum load 7 m
2
10 m
2
Carriage maximum stroke
2760 mm
3820 mm [GLOBELV1]
2760 mm
3820 mm [GLOBEL1-GLOBELV1]
Service class 3 - FREQUENT 3 - FREQUENT
Intermittence
S2 = 30 min
S3 = 50%
S2 = 30 min
S3 = 50%
Temperature -20° C / +55° C -20° C / +55° C
Degree of protection IP10 IP10
Control panel 70R 71R
F1 fuse F1,6A F1,6A
Motor power supply 24 V= / 8 A 24 V= / 12 A
Accessories power supply 24 V= / 0,3 A 24 V= / 0,3 A
Control panel 70R 71R
F1 fuse F3,15A F3,15A
Motor power supply 24 V= / 8 A 24 V= / 12 A
Accessories power supply 24 V= / 0,3 A 24 V= / 0,3 A